Header Span Chart

A header carries the load above a door or window opening. This chart gives typical maximum opening widths for doubled headers supporting one floor or roof — always confirm against code.

Header (doubled) Max opening
(2) 2×6 up to about 4 ft
(2) 2×8 up to about 5 ft
(2) 2×10 up to about 6 ft 6 in
(2) 2×12 up to about 8 ft
Load changes everything. These assume a typical light load. Headers carrying two floors or wide roof spans must be larger or engineered. Verify with a span table or professional.

Estimates for planning only — confirm load-bearing headers with code or an engineer.

FAQ

Does header span depend on the load above it? Yes, significantly. A header supporting just roof load can span farther than one carrying an additional floor above it, which is why header span tables are organized by both span distance and the load condition (roof only versus roof plus floor).

See the Joist Span Chart and Beam Span Chart.

What a header does

A header carries the weight above a door or window opening and passes it to the studs on either side of the opening. The wider the opening and the more load above, the deeper the header needs to be. Doubled headers are two boards fastened together, often with a spacer so the total thickness matches the wall.

Using the chart safely

The figures are typical maximums and depend on lumber species and grade, the load carried, and local snow and wind conditions. A wide opening or a heavy load calls for a deeper header or an engineered beam. Make sure the header ends bear on jack studs that sit on a solid path to the foundation, and confirm your design with the local code or an engineer.

Scroll to Top

The calculators and tools on Formula Factory are provided for general guidance and informational purposes only. Results are estimates based on standard formulas and the values you enter — they do not constitute professional engineering, electrical, or architectural advice. Always verify calculations with a qualified professional before making decisions for any safety-critical, code-compliance, or commercial application. Formula Factory makes no representations or warranties as to the accuracy or completeness of any result, and accepts no liability for errors, omissions, or any outcomes arising from reliance on this information.