Window Energy Loss Calculator

DOORS & WINDOWS

Estimate how fast heat moves through a window. Pick the window type or enter a U-factor, set the size and the indoor and outdoor temperatures, and get the heat-loss rate.

WarmColdglass
Heat Loss Rate
— BTU/hr
Steady-state conductive loss at the entered temperature difference.

Usage Tip

Lowering U-factor and sealing air leaks both cut heat loss — a leaky high-efficiency window can still perform poorly. Check the NFRC label for the whole-window U-factor.

THE MATH
Area (ft²) = (Width / 12) × (Height / 12)
Q = U × Area × ΔT
ΔT = Indoor temp − Outdoor temp
U-factor is the conductive heat transfer rate per square foot per degree F — lower is better. Q is the steady-state heat-loss rate in BTU per hour.
One watt ≈ 3.412 BTU/hr.
This is steady-state conductive loss only. It does not include air leakage around the sash, solar heat gain, or framing effects, so real-world performance varies.
U-factors come from the NFRC label on the window; whole-window U-factors run higher than center-of-glass values.
Typical U-factors: single-pane near 1.0, double-pane clear near 0.5, double-pane Low-E near 0.3, triple-pane Low-E near 0.2.
Practical Notes

The heat lost through a window is its area multiplied by its U factor and the temperature difference between inside and outside. The U factor measures how easily heat passes through the window, and a lower number means better insulation. A single pane window is roughly three times worse than a good double pane low E window.

Air leaks add to the loss, so check that the window is sealed as well. Heavy curtains, storm windows, and window films can reduce the loss from windows you cannot replace. The result is an estimate in units of heat per hour, and the real loss changes with wind and sun. Ratings on new windows are shown on a label from a national rating council.

Spotted an error or have a suggestion for this calculator? Let us know →
Scroll to Top

The calculators and tools on Formula Factory are provided for general guidance and informational purposes only. Results are estimates based on standard formulas and the values you enter — they do not constitute professional engineering, electrical, or architectural advice. Always verify calculations with a qualified professional before making decisions for any safety-critical, code-compliance, or commercial application. Formula Factory makes no representations or warranties as to the accuracy or completeness of any result, and accepts no liability for errors, omissions, or any outcomes arising from reliance on this information.