Estimate how fast heat moves through a window. Pick the window type or enter a U-factor, set the size and the indoor and outdoor temperatures, and get the heat-loss rate.
Usage Tip
Lowering U-factor and sealing air leaks both cut heat loss — a leaky high-efficiency window can still perform poorly. Check the NFRC label for the whole-window U-factor.
Q = U × Area × ΔT
ΔT = Indoor temp − Outdoor temp
One watt ≈ 3.412 BTU/hr.
U-factors come from the NFRC label on the window; whole-window U-factors run higher than center-of-glass values.
Typical U-factors: single-pane near 1.0, double-pane clear near 0.5, double-pane Low-E near 0.3, triple-pane Low-E near 0.2.
The heat lost through a window is its area multiplied by its U factor and the temperature difference between inside and outside. The U factor measures how easily heat passes through the window, and a lower number means better insulation. A single pane window is roughly three times worse than a good double pane low E window.
Air leaks add to the loss, so check that the window is sealed as well. Heavy curtains, storm windows, and window films can reduce the loss from windows you cannot replace. The result is an estimate in units of heat per hour, and the real loss changes with wind and sun. Ratings on new windows are shown on a label from a national rating council.