PVC Pipe Dimensions

PVC follows iron pipe size (IPS), so it shares outside diameters with steel pipe of the same schedule. This chart gives Schedule 40 PVC outside and inside diameters.

Nominal OD (in) Sch 40 ID
1/2 in 0.840 0.602
3/4 in 1.050 0.804
1 in 1.315 1.029
1-1/2 in 1.900 1.610
2 in 2.375 2.067
3 in 3.500 3.068
4 in 4.500 4.026
Nominal is not the OD. Like steel, a 1-inch PVC pipe has a 1.315 in outside diameter. Schedule 80 has thicker walls and a smaller bore for higher pressure.

FAQ

Does PVC pipe come in the same sizes as PEX? PVC uses standard nominal pipe sizes similar to copper, but its wall thickness and actual inside diameter differ from both copper and PEX at the same nominal size, so always confirm actual dimensions when connecting different pipe materials. When transitioning between PVC and another pipe material, use a rated transition fitting rather than assuming a direct thread or slip match.

See the Pipe Schedule Chart and Pipe Thread Dimensions.

Schedule 40 and Schedule 80

Pipe of a given nominal size has the same outside diameter whatever its schedule, so fittings fit both. Schedule 80 has thicker walls, which means a smaller inside diameter and a higher pressure rating than Schedule 40. The inside diameter in the chart is what governs flow.

Using PVC properly

PVC is joined by solvent welding with primer and cement, and the joint needs time to cure before it is pressurized. The pressure rating of PVC drops as the temperature rises, and standard PVC is not intended for hot water lines, where CPVC is used instead. Check the markings on the pipe for its schedule and rating before you install it.

Scroll to Top

The calculators and tools on Formula Factory are provided for general guidance and informational purposes only. Results are estimates based on standard formulas and the values you enter — they do not constitute professional engineering, electrical, or architectural advice. Always verify calculations with a qualified professional before making decisions for any safety-critical, code-compliance, or commercial application. Formula Factory makes no representations or warranties as to the accuracy or completeness of any result, and accepts no liability for errors, omissions, or any outcomes arising from reliance on this information.